KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-
10 KXE-TM-BA_IA-e-1411 3 Basic Information (General) 3.1 Proper use The display unit acquired by you is used in combination with a platform a
KXE-TM-BA_IA-e-1411 11 3.4 Monitoring of Test Resources In the framework of quality assurance the measuring-related properties of the display un
12 KXE-TM-BA_IA-e-1411 6 Unpacking and placing 6.1 Installation Site, Location of Use The display units are designed in a way that reliable w
KXE-TM-BA_IA-e-1411 13 6.4 Transport Securing Please note, if the display unit is used together with platform with transportation lock, this tr
14 KXE-TM-BA_IA-e-1411 6.7 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each display unit w
KXE-TM-BA_IA-e-1411 15 6.8.1 Position of seals and adjusting switch unlocked locked 6.8.2 Software version check Switch on the device
16 KXE-TM-BA_IA-e-1411 7 Basic Operation 7.1 Start-up Press and the instrument will carry out a self-test. As soon as the weight display ap
KXE-TM-BA_IA-e-1411 17 7.5 Switch-over weighing unit The following setting must be allocated to a functional button (see chap. 9.). Functional
18 KXE-TM-BA_IA-e-1411 7.6.2 Pre-tare deduction (PRE-TARE) The known dead weight of a weighing container can be tared off by entering its weig
KXE-TM-BA_IA-e-1411 19 8 Totalization Settings of functional menu: In the following application example of application the following settings a
2 KXE-TM-BA_IA-e-1411 GB KERN KXE-TM Version 1.1 06/2014 Operating and installation instructions Display device Contents 1 Technical d
20 KXE-TM-BA_IA-e-1411 Add up: 1. Place weighing good A, e.g. 5 kg. Wait for stability, then press . The weight value is added-up into a su
KXE-TM-BA_IA-e-1411 21 Delete total added memory: With display „Number of weighings“ or „Total weight“ press + at the same time. The data
22 KXE-TM-BA_IA-e-1411 9 Function menu Call up menu: In weighing mode press and at the same time, the functional menu „01 FnC“ is dis
KXE-TM-BA_IA-e-1411 23 Navigation in the menu: Invoke function menu , see chap. 9 and acknowledge with . Select the individual functio
24 KXE-TM-BA_IA-e-1411 9.1 Overview Factory settings are marked by *. No. Function Available settings Parameters Description FNC-00 Keyboa
KXE-TM-BA_IA-e-1411 25 FNC-03 Allocation functional buttons 0* Print 1 Switch-over weighing unit 2 M+ (adding up / printing) 3 MC (delet
26 KXE-TM-BA_IA-e-1411 FNC-06 Tone 0 Signal tone switched off 1* Signal tone switched on FNC-07 Peak value function 0* switched off 1 M
KXE-TM-BA_IA-e-1411 27 10 Description of individual functions 10.1 Resetting the menu Reset all parameters to factory default: to switch on the
28 KXE-TM-BA_IA-e-1411 10.2 Display higher resolution Condition: The following setting must be allocated to a functional button (see chap. 9.
KXE-TM-BA_IA-e-1411 29 10.3 Peak value function This function displays the highest load value (peak value) of a weighing. The peak value remai
KXE-TM-BA_IA-e-1411 3 7 Basic Operation ... 16 7.1
30 KXE-TM-BA_IA-e-1411 11 Service, maintenance, disposal Before any maintenance, cleaning and repair work disconnect the appliance from the op
KXE-TM-BA_IA-e-1411 31 11.4 Error messages Error message Description Err 0 Value outside the A/D changer range Err 2 Weighing value ≤ Zero ra
32 KXE-TM-BA_IA-e-1411 12 Instant help In case of an error in the program process, briefly turn off the display unit and disconnect from power
KXE-TM-BA_IA-e-1411 33 13 Installation display unit / platform Installation / configuration of the weighing system must be carried out by a well
34 KXE-TM-BA_IA-e-1411 13.2 How to connect the platform Disconnect the display unit from the power supply. Connect load cell cable to the conne
KXE-TM-BA_IA-e-1411 35 14 Technician menu • In verified weighing systems the access to the technician menu is locked. In order to unlock the
36 KXE-TM-BA_IA-e-1411 14.1 Configure / Menu item Navigation in the menu: Invoke configuration menu and confirm with . The first fu
KXE-TM-BA_IA-e-1411 37 Configuration menu overview: Factory settings or allowed settings for verified weighing systems are marked with *. No.
38 KXE-TM-BA_IA-e-1411 CSP-04 Zero-Tracking Automatic zero point correction by changing the display, digits / time selectable 0.25 d 0.25
KXE-TM-BA_IA-e-1411 39 14.2 Adjust / Menu item • The weight to be used depends on the capacity of the scale. Carry out adjustment as near a
4 KXE-TM-BA_IA-e-1411 1 Technical data KERN KXE-TM Display 6-digit Solution verifiable Single (Max.) 5.000 e Dual (Max.) 10.000 e Verifica
40 KXE-TM-BA_IA-e-1411 Ensure that there are no objects on the weighing plate. Wait for stability, then press . After approx. 5 second
KXE-TM-BA_IA-e-1411 41 14.3 Enter password / Menu item The technician and function menu can be secured against non authorised access by a pass
42 KXE-TM-BA_IA-e-1411 14.3.2 Password input for access to menu Example: Invoke technician menu When invoking a menu, the password inquir
KXE-TM-BA_IA-e-1411 43 14.4 Change appliance settings / menu item Navigation in the menu: Invoke menu item and confirm with . The fir
44 KXE-TM-BA_IA-e-1411 Menu overview Factory settings or allowed settings for verified weighing systems are marked with *. No. Function Avai
KXE-TM-BA_IA-e-1411 45 CFN-05 Animal weighing mode 0 Deactivated, always use this setting. 1 Not documented 2 Not documented CFN-06 Not docume
KXE-TM-BA_IA-e-1411 5 Dimensions: 1. With wall support 2. Without wall support
6 KXE-TM-BA_IA-e-1411 2 Appliance overview 1. Weight display 2. Battery compartment 3. RS-232 (disabled) 4. Connection
KXE-TM-BA_IA-e-1411 7 2.1 Keyboard overview Key Function • Turn on/off • Quit • Back to menu / weighing mode • Zeroing • Taring •
8 KXE-TM-BA_IA-e-1411 2.1.1 Numerical input via the navigation buttons Key Function 1. Scroll forward in menu • Increase flashing digit
KXE-TM-BA_IA-e-1411 9 2.3 Overview of display Indicator [] next to symbol displays: TAREthat a tare value is stored Instable weighing value
Komentarze do niniejszej Instrukcji