KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-
In the menu you can activate the AUTO-OFF function (see chap. 8.4.2 “Automatic switch-off function“). According to the selected settings, the balanc
Procedure when adjusting: Observe stable environmental conditions. A warming up time (see chapter 1; Technical Data) is required for stabilization.
Models FOB-NL: Balance display Operation (example) Switch off the balance Press and hold , press 3x at the same time, release - an
6 Operating elements 6.1 Keyboard overview 6.1.1 Models FOB-NS: Button Designation Pressed once and released [ON/OFF] • Turn on/off • Call u
6.1.2 Models FOB-NL: Button Designation Pressed once and released [ON/OFF] • Turn on/off • Call up adjustment (press and hold button) [TARE]
6.2 Overview of display 6.2.1 Models FOB-NS: Display Description g, lb, oz, ozt, dwt Display weighing units Stability display 6.2.2 Mode
7 Operation 7.1 Simple weighing Balance display Operation Start balance by pressing . The balance will carry out a self-test. Wait for „0“ d
7.2 Taring The dead weight of any weighing container may be tared away by pressing a button, so that the following weighing procedures show the net
7.4 Hold function (only "L" models) The balance has an integrated standstill function (mean value calculation). With this it is possible
2. Balance display Operation Start balance by pressing . The balance will carry out a self-test. Wait for „0“ display (example) P
GB KERN FOB-N Version 1.0 09/2014 Operating manual Compact balance Contents 1 Technical data ...
8 The menu 8.1 Call up menu „L“-Models: • Switch off the balance • Press and hold and press 3x at the same time, then release both buttons.
8.3 Menu overview 8.3.1 Models FOB-NS: *not documented 8.3.2 Models FOB-NL: FOB-N-BA-e-1410 21
8.4 Menu settings 8.4.1 Setting weighing units Balance display Operation FOB-S: In weighing mode press button for approx. 3 seconds.
Press repeatedly until „Unit“ is displayed Press , „A.Off“ will be shown Press , „CAP.“ is displayed Press , „End“ is displaye
8.4.2 Automatic switch-off function „AUTO OFF“ in stand-by mode The balance offers the possibility of the automatic switch-off, when the balance is
Use or to adopt selection, „AOFF“ is displayed Press , „CAP“ is displayed Press again, „End“ is displayed Using or the bal
9 Error messages Battery empty Insert new battery or connect the balance to power supply Weighing range exceeded Remove load and set balance to z
11 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process mus
8 The menu ... 20 8.1 Call up menu ...
1 Technical data Models „FOB-NS“: KERN FOB 0.5K-4NS FOB 5K-3NS Readability (d) 0.1 g 1 g Weighing range (max) 500 g 5000 g Reproducibility
Models „FOB-NL“: KERN FOB 7K-4NL FOB 10K-3NL FOB 30K-3NL Readability (d) 0.5 g / 1 g 1 g / 2 g 2 g / 5 g Weighing range (max) 5 kg / 7.5 kg
2 Basic Information (General) 2.1 Proper use The balance you purchased is intended to determine the weighing value of material to be weighed. It
2.4 Monitoring of Test Resources In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testi
5 Unpacking, Setup and Commissioning 5.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are a
5.2.1 Placing The balance must be installed in a way that the weighing plate is exactly in horizontal position. 5.2.2 Scope of delivery Serial ac
Komentarze do niniejszej Instrukcji